Property | Base material | Standard | |
Kingflex ULT | Kingflex LT | Test Method | |
Thermal Conductivity | -100°C, 0.028 -165°C, 0.021 | 0°C, 0.033 -50°C, 0.028 | ASTM C177 |
Density Range | 60-80Kg/m3 | 40-60Kg/m3 | ASTM D1622 |
Recommend Operation Temperature | -200°C to 125°C | -50°C to 105°C | |
Percentage Of Close Areas | >95% | >95% | ASTM D2856 |
Moisture Performance Factor | NA | <1.96x10g(m.m.Pa) | ASTM E 96 |
Wet resistance Factor μ | NA | >10000 | EN12086 EN13469 |
Water Vapor Permeability Coefficient | NA | 0.0039g/h.m2 (25mm thickness) | ASTM E 96 |
PH | ≥8.0 | ≥8.0 | ASTM C871 |
Tensile Strength Mpa | -100°C, 0.30 -165°C, 0.25 | 0°C, 0.15 -50°C, 0.218 | ASTM D1623 |
Comprssive Strength Mpa | -100°C, ≤0.3 | -40°C, ≤0.16 | ASTM D1621 |
Kingflex Dimension | ||||
Inches | mm | Size(L*W) | ㎡/Roll | |
3/4" | 20 | 10 × 1 | 10 | |
1" | 25 | 8 × 1 | 8 |